Laboratory open · Mon–Sat 08:30–17:30 (GMT+8) CNAS L7721 accredited · ILAC-MRA mutual recognition
Home/Accreditation

Accreditation & certificates

Accreditation is what makes a report usable outside the factory gate. What the laboratory holds is set out below in full.

Status

Accreditation held

One competence standard, one certificate, one registration number.

ISO/IEC 17025:2017 — Testing

Competence of the testing laboratory, assessed by the China National Accreditation Service for Conformity Assessment (CNAS) under CNAS-CL01.

Accredited entityHigh Voltage Electrical Testing Center of Yonggu Group Co., Ltd.
Registration no.CNAS L7721
Effective date27 May 2024
Expiry date26 May 2030
ActivityTesting
Scope~200 test items across ~80 national standards

The accredited scope is defined by the schedule attached to the certificate, which bears the same registration number and forms part of the certificate. The full schedule is available on request.

ILAC-MRA mutual recognition

CNAS is a signatory of the ILAC Mutual Recognition Arrangement and of the APAC Mutual Recognition Arrangement. Reports covering items inside the accredited scope carry the accreditation mark and are recognised by the accreditation bodies and regulators of the other signatory economies.

For an overseas buyer, a customs officer or a utility engineer, this is the mechanism that makes a Chinese test report readable without a second opinion — which is the whole reason the report is worth commissioning.

How to verify one of our reports
Scope

Accredited scope at a glance

A summary of the product families and standards covered — transmission and distribution materials as well as high- and low-voltage electrical products. The full schedule runs to many pages and is available on request, or from the CNAS register.

Product familyStandards in scopeAccredited test items
Power cables & wires IEC 60502, IEC 60227, IEC 61089, GB/T 12706, GB/T 5023 Conductor DC resistance, insulation thickness, AC withstand, partial discharge, ageing
Power fittings IEC 61284, GB/T 2314, GB/T 14315, GB/T 9327, DL/T 2340, DL/T 2341 Failing load, slip load, galvanising mass, hardness, dimensions, DC resistance
Cable accessories
1–35 kV
IEC 60502, GB/T 12706, GB/T 9327 Power-frequency withstand, partial discharge, thermal cycling, heat ageing
Insulators & arresters IEC 61109, IEC 60099-4, GB/T 19519, GB/T 11032 Withstand voltage, lightning impulse, mechanical failing load, ageing
HV switchgear & distribution apparatus IEC 62271-1, IEC 62271-100, IEC 62271-102, IEC 62271-103, IEC 62271-200, IEC 60282-1, GB/T 11022, GB/T 1984, GB/T 1985, GB/T 3906, GB/T 15166 Withstand voltage, lightning impulse, temperature rise, mechanical operation, short-time current, over-current
LV electrical products IEC 61439-1, IEC 60947-1, IEC 60947-2, IEC 60529, GB/T 7251.1, GB/T 14048.1, GB/T 14048.2 Withstand voltage, temperature rise, mechanical operation, over-current, enclosure and IP checks
Copper & aluminium products IEC 61089, GB/T 3190, GB/T 5231, GB/T 5585 Composition, tensile strength, elongation, DC resistivity, dimensional tolerance

Standard numbers are listed as the editions currently in the schedule. The accredited schedule itself lists Chinese national (GB) standards; equivalent IEC and EN methods are performed under the same quality system, and a result is only presented as accredited where the method concerned is inside the schedule. Where a customer specifies a different edition or an IEC equivalent, this is confirmed at the test plan stage.

Interpreting the mark

What an accredited result means

  • The test method and the laboratory's competence for that method have been assessed by an accreditation body
  • The report may carry the accreditation mark and the registration number CNAS L7721
  • The result is recognised under the ILAC and APAC mutual recognition arrangements
  • Instruments used are traceable and their calibration records are retained with the raw data
  • Accreditation does not mean a product conforms — it means the test was performed competently. The conclusion in the report applies to the sample tested

Authorised signatories

Reports are signed by engineers listed in the accreditation schedule. The signature, the report number and the online verification record must all agree for a report to be valid.

A report without a report number, or one whose number cannot be found, is not ours. Please send a scan to lab@yongutest.com and we will confirm in writing.
Request the list of signatories
Competence

Technical competence

The laboratory is a CNAS L7721-accredited testing laboratory for power cables and wires, power fittings, cable accessories, insulators, surge arresters, fuses and other HV/LV electrical equipment. Six specialised laboratories carry out electrical, mechanical, material, ageing and non-destructive testing to IEC, GB and EN standards, and issue English-language reports recognised under the ILAC Mutual Recognition Arrangement.

What it claims is verifiable: that the tests are performed and reported in accordance with ISO/IEC 17025:2017; that results are recorded as measured; and that no result is altered, withheld or re-issued to a different value for commercial reasons.

The safeguards that support that claim are structural rather than promises:

  • The laboratory operates its own quality system and is audited by CNAS on a fixed cycle, independently of the sales function
  • Every report is technically reviewed before release, and the review covers the raw data, not just the summary
  • Test engineers are appointed on technical competence and are not assessed on the pass rate of the samples they test
  • A non-conforming result is issued as a non-conforming result; it cannot be withdrawn at the request of a customer or a group company
  • Complaints and appeals are reviewed by the technical review function, not by the commercial team

Need the certificate and schedule?

Send us the tender clause. We will return the certificate, the relevant schedule pages and a note on which of your test items are inside the accredited scope.